E C O W A C

EcoMax Flow

EcoMax Flow

EcoMax Flow

EcoMax Flow, it operates effectively in all types of industrial environments with high efficiency, low energy consumption, and long-lasting performance features.
  • Capacity : 17-500 m3h

Monoblock vacuum pumps have secured a strong position in industrial vacuum solutions with their compact design and high-performance structure. Thanks to their space-saving design, they offer businesses both ease of installation and high efficiency. ECOWAC monoblock vacuum pumps are specifically designed to maximize efficiency in your operations by providing reliable vacuum performance, especially in tight spaces and sensitive work processes.

  1. Sealing with Long-Lasting Mechanical Seal
  2. Protection with Cavitation Valve
  3. Space Saving with Compact Design
  4. Optimized Energy Efficiency
  5. Exproof Options for Safety and Protection
  6. Quiet Operation Technology
  7. Innovative Cooling System
  8. Industry 4.0 Compatibility

 

MODEL Inlet
And
Outlet
Absolute
Pressure
mbar 400 200 100 80 60 40 33 Service
Water
(lt/min)
torr 300 150 75 60 45 30 25
Vacuum mmHg -460 -610 -685 -700 -715 -730 -735
Motor
(kW)
Speed
(rpm)
Intake Capacity (m3/h)
EcoMax Flow 100075 G 1” 0.75 2850 25 24 23 22 21 20 17 4
EcoMax Flow 100015 G 1” 1.5 2850 60 55 45 40 36 30 28 6
EcoMax Flow 200022 G 1,5” 2.2 2850 80 78 72 66 62 55 50 8
EcoMax Flow 200004 G 1,5” 4 2850 112 110 109 105 100 90 80 10
EcoMax Flow 300022 DN 40 2.2 1450 80 80 79 78 77 75 70 13
EcoMax Flow 300003 DN 40 3 1450 112 110 109 108 105 100 95 15
EcoMax Flow 300004 DN 40 4 1450 145 143 141 140 132 115 110 16
EcoMax Flow 400055 DN 50 5.5 1450 200 197 195 190 185 175 170 18
EcoMax Flow 400155 DN 50 5.5 1450 225 224 223 219 210 205 200 20
EcoMax Flow 500075 DN 65 7.5 1450 280 282 280 275 270 240 220 23
EcoMax Flow 500011 DN 65 11 1450 382 364 347 332 312 300 290 25
EcoMax Flow 500015 DN 65 15 1450 420 400 381 365 343 330 319 30

The values in the table are valid under the following conditions: air at 20°C, service water at 15°C, and an atmospheric pressure of 760 mmHg.
The service water flow rates are calculated at the pump's maximum achievable vacuum pressure and under conditions where no circulation tank is used.
The values specified in the table are subject to a tolerance range of ±%10