EcoMax Twin , it can operate efficiently in any industrial environment with features such as high efficiency, low energy consumption, and long-lasting use.
  • Capacity : 35-3000 m3h

ECOWAC two-stage vacuum pumps are designed to meet industrial vacuum needs with high performance, durability, and energy efficiency. The dual-stage design enables the pumps to achieve deeper vacuum levels while also optimizing energy consumption.

  1. Seal with Long-lasting Mechanical Gasket
  2. Protection with Cavitation Valve
  3. Two-stage Pressure Reduction
  4. Optimized Energy Efficiency
  5. Exproof Options for Safety and Protection
  6. Silent Operation Technology
  7. Innovative Cooling System
  8. Industry 4.0 Compatibility

 

MODEL Inlet
and
Outlet
Absolute
Pressure
mbar 400 200 100 80 60 40 33 Service
Water
(lt/min)
torr 300 150 75 60 45 30 25
Vacuum mmHg -460 -610 -685 -700 -715 -730 -735
Motor
(kW)
Speed
(rpm)
Airflow Capacity (m3/h)
EcoMax Twin 600003 DN 32 3 1450 54 54 54 53 48 40 35 6
EcoMax Twin 600004 DN 40 4 1450 110 108 105 97 85 70 55 12
EcoMax Twin 700055 DN 40 5,5 1450 160 155 145 140 130 110 100 14
EcoMax Twin 700155 DN 40 5,5 1450 200 190 190 185 165 140 120 16
EcoMax Twin 800011 DN 50 11 1450 280 270 270 250 215 190 180 30
EcoMax Twin 800111 DN 50 11 1450 360 350 345 325 290 240 220 35
EcoMax Twin 800015 DN 50 15 1450 460 440 420 400 360 300 275 45
EcoMax Twin 900011 DN 50 11 1450 290 280 280 260 220 190 180 30
EcoMax Twin 900211 DN 50 11 1450 360 350 350 340 300 240 220 35
EcoMax Twin 900015 DN 50 15 1450 450 440 440 420 360 290 250 40
EcoMax Twin 110011 DN 65 15 1450 500 490 480 470 400 360   40
EcoMax Twin 110185 DN 65 18,5 1450 565 560 560 540 460 400   45
EcoMax Twin 110022 DN 80 22 1450 670 660 650 630 540 440   50
EcoMax Twin 120185 DN 80 18,5 1450 680 670 630 610 505 440   50
EcoMax Twin 120017 DN 80 22 1450 790 780 760 720 610 520   60
EcoMax Twin 120030 DN 80 30 1450 890 870 860 810 700 570   65
EcoMax Twin 120037 DN 100 37 980 1200 1150 1100 1050 1000 800   100
EcoMax Twin 120045 DN 100 45 980 1600 1550 1500 1450 1400 1000   110
EcoMax Twin 120055 DN 100 55 980 2000 1950 1900         150
EcoMax Twin 120075 DN 150 75 735 2100 2000 1900         170
EcoMax Twin 120090 DN 150 90 735 2700 2600 2500         210

The values in the table are valid under the following conditions: air at 20°C, service water at 15°C, and an atmospheric pressure of 760 mmHg.
The service water flow rates are calculated at the pump's maximum achievable vacuum pressure and under conditions where no circulation tank is used.
The values specified in the table are subject to a tolerance range of ±%10